 >> Products >> B-type Ultrasonic Diagnostic Apparatus


RO-3000 series

Laptop(New) 
3000D1 
3000D2
3000G1 
3000G2  

Laptop(New)

  This B ultrasound system is a portable electronic convex scanning ultrasound tomography inspection device with digital scanning conversion. It has the features of small bulk, light weight, large LCD screen display and no eradiation.

Features£º

  1. 3.5MHZ 80 elements high-sensitive convex probe£¬ Optional: 5-7.5 MHz high-frequency probe.

  2. 15¡åTFT  LCD (abbr. Liquid Crystal Display)

  3. Long life, little noise.

  4. image processing, variable aperture, multi-stage electronic focusing, logarithmic compression, continuous STC control, dynamic echo filtering, image enhancement, line correlation, frame correlation, linear interpolation, etc.

  5. LCD, high-sensitive imaging, various gray scales, definite imaging, high-resolution ratio.

  6. Display mode: B, B/B, 4B, 8B,B+M and M imaging mode

  7. Detectable Depth:3.5MHz¡Ý160 mm

  8. Magnification: ¡Á1.0, ¡Á1.2, ¡Á1.5, 2.0. ¡Á1.5, ¡Á2.0, with depth-downward function

  9. Gray Scale:256

  10. L ine Number for Each Frame:160

  11. Resolving Power:Vertical ¡Ü1.0mm (depth¡Ü80mm);

                     ¡Ü2.0mm (80mm<depth¡Ü130mm)£»
   Horizontal   ¡Ü2.0mm (depth¡Ü80mm)£»
                      ¡Ü3.0mm (80mm<depth¡Ü130mm)

  1. Geometrical Precision: Vertical ¡Ü5%    Horizontal ¡Ü8%

  2. Blind Zone:¡Ü5mm

  3. Character Display: Multi-remarks of name, gender, age, number, various marks of body location

  • Focusing: Variable aperture, 1-, 2-, 3-, and 4-stage dynamic focusing for arbitrary option.

  • Measurements: Distance, area/perimeter, cubage, HR and gestational week£¨AC,HC,FL,BPD, GS ,CRL£©, etc

  • Note Function: Name, Age, Sex£¬number of patient recorder, diagnostic date, 24 markers of body location, remarks in full screen, etc.

  • Gain Control: 6-segment STC segmentation control, full gain control

  • Image Polarity: left/right turn, positive /negative turn and up / down turn

  • Image Memory: 128 frames

  • Cine Loop and Frame: successive 128 frames

  • Pseudo Color Function: 8 colors

  • ¦Ã rectification and pseudo color display, character remarks in screen, Chinese or English conversion of name, gender, age, number at fixed remarks, FPGA designation.

  • Video out: VGA

  • Output Interface: two output interfaces, VGA and PAL video signal outputs, can choose to connect video printer

  • Standard configuration: VGA video output external interface to connect with the monitor, video tape recorder, video image recorder.

  • Power Supply Range: AC 220V¡À22V   50Hz¡À1Hz

  • Input Power: ¡Ü260VA

  • Work time: ¡Ý8h

  • Weight ¡Ö6.8kg

  • Shell Size:384mm¡Á300mm¡Á125mm


3000D1 B Ultrasonic Instrument

Features

  1. With the advance of DSC and SMT, the apparatus is more reliable compared with other products.

  2. By adopting multistage dynamic focalizing, variable aperture, digital scanning, related digital graphic processing, etc,. the apparatus can provide sensitive, steady, clear, high-resolution pictures.

  1. Equipped with B, B+B, B+M,M display modes and the 256 gray scales screen.

  2. Display frozen pictures, two pictures in the same frame, and freeze one of the two pictures or both the two pictures. Moreover, the displayed picture has the feature of polarity reversal and bilateral reversal.

  3. Magnifications of picture are adjustable in the process of operation.

  4. Upgrade of the depth of the picture.

  5. Full screen editable characters, real-time clock, body-position indication, operation indicator of Route Ball Mouse.

  6. Multi-measurement of length, perimeter, area, M-type conventional examination and gestational measurement.

  7. Terminal output of standard PAL system, which will meet the requirement of different users.

  8. Soft-touch keyboard, plastic exterior case, which are good-looking, portable, and convenient to operate.

Applicable fields

  1. Suitable of diagnosis of heart, liver, gallbladder, kidney, spleen, pancreas, thyroid gland, uterus, bladder and etc.

  2. Widely used for clinical examination and diagnosis of abdomen and department of obstetrics and gynecology in the hospitals of county, rural-town and town.

  3. Used in the examinations of early pregnancy, contraceptive ring, perinatal period of pregnant woman, etc.

Configuration Probe

3£®5MHz Convex Probe£¨R=60£©

Optional Probe

6£®5MHz Convex Probe£¨Transvaginal R=13£©
7.5MHz High Frequency Linear Probe

Depth Scope£¨mm£©

0-200mm

Maximal Scanning Depth£¨mm£©

¡Ý170

Resolution
£¨mm£©

Horizontal

¡Ü3£¨Depth¡Ü80mm£©
¡Ü4£¨80mm<Depth¡Ü130mm£©

Vertical

¡Ü1£¨Depth¡Ü80mm£©
¡Ü2£¨80mm<Depth¡Ü130mm£©

Blind Area£¨mm£©

¡Ü4

Accurancy£¨%£©

Horizontal

¡Ü10

Vertical

¡Ü5

Monitor

10 inches

Display Mode

B¡¢B+B¡¢B+M¡¢M

Gray Scale

256

Magnification

¡Á1.0£¬¡Á1.2£¬¡Á1.5£¬¡Á2

Cineloop

256 frames

Clock

Time Display

Electronic Focus

4 focus at radom

Frame correlation

B¡¢B+B

Image Reversal

Up/Down¡¢Left/Right¡¢Black/White

Measurement

Distance¡¢Perimeter¡¢area¡¢heart rate¡¢pregnant weeks

Character Mark

Date, ID, Age, Sex, Focus, Frame Correlation, Full Screen Character

Body Mark

18 kinds

Power Consumption£¨MAX£©

110VA

¡¡


3000D2 B Ultrasonic Instrument
     3000D2 adopts lots of advanced electrical and faced technique. Digital transmitting focus control improve the precision of the transmitting point which improve the image distinguish; low noise, wide frequency band receiving amplification circuit enriches the message which make the image gradation is outstanding; lots of image disposing function make the image is clear and exquiste.

Main features of Convex Probe:


Serial No.

Features

Specifications

1

Probe Frequency Rating MHz

3.5

2.5 (frequency conversion)

5.0 (frequency conversion

2

Horizontal Resolution,mm

¡Ü3(Depth¡Ü80)
¡Ü4(80<Depth¡Ü130)

¡Ü3(Depth¡Ü80)
¡Ü5(80< Depth¡Ü160)

¡Ü2(Depth¡Ü40)
¡Ü3(40< Depth¡Ü80)

3

Vertical Resolution, mm

¡Ü2(Depth¡Ü80)
¡Ü3(80<Depth¡Ü130)

¡Ü2(Depth¡Ü130)
¡Ü3(130<Depth¡Ü170)

¡Ü1(Depth¡Ü40)
¡Ü2(40<Depth¡Ü80)

4

Blind Area, mm

¡Ü5

¡Ü6

¡Ü3

5

Maximum depth of detection, mm

¡Ý160

¡Ý180

¡Ý100

6

Accuracy error of geometric position %

Horizontal¡Ü15
Vertical¡Ü10

Horizontal¡Ü15
Vertical¡Ü10

Horizontal¡Ü10
Vertical¡Ü10

 Main features of Transvaginal Probe:


Serial No.

Features

Specifications

1

Probe Frequency Rating MHz

6.5

5.5 (frequency conversion)

8.0(frequency conversion

2

Horizontal Resolution,mm

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

3

Vertical Resolution, mm

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

4

Blind Area, mm

¡Ü7

¡Ü7

¡Ü7

5

Maximum depth of detection, mm

¡Ý60

¡Ý70

¡Ý60

6

Accuracy error of geometric position %

Horizontal¡Ü10
Vertical¡Ü5

Horizontal¡Ü10
Vertical¡Ü5

Horizontal¡Ü10
Vertical¡Ü5

Main features of High Frequency Linear Probe:


Serial No.

Features

Specifications

1

Probe Frequency Rating MHz

7.5

6.0(frequency conversion)

9.0(frequency conversion

2

Horizontal Resolution,mm

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

3

Vertical Resolution, mm

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

¡Ü1(Depth¡Ü40)

4

Blind Area, mm

¡Ü4

¡Ü4

¡Ü4

5

Maximum depth of detection, mm

¡Ý60

¡Ý60

¡Ý60

6

Accuracy error of geometric position %

Horizontal¡Ü5
Vertical¡Ü5

Horizontal¡Ü5
Vertical¡Ü5

Horizontal¡Ü5
Vertical¡Ü5

Working Mode


Scanning Mode

Linear, Convex, Double connectors

Scanning Line

512

Display Mode

B¡¢B/B¡¢B/M¡¢M

Focus

Electronic Focusing, Acoustic lens focusing

In B¡¢B/B Mode

Single Focus¡¢Double Focus¡¢Three Focus¡¢Four Focus

In B/M¡¢M Mode

Single Focus for four areas

Features

Gray

256

Display depth

Convex Probe Maximum 220mm£¬scroll
Transvaginal Probe Maximum 120mm,scroll
High frequency Maximum 120mm£¬scroll

Picture analyse

3 levels of working frequency

Left/Right Reverse

8 levels of edge enhancement

Up/Down Reverse

8 levels of dynamic range

Positive/Negative Reverse

4 levels of frame average processing

4 Magnification rates

4 kinds of gamma correction

Gain control

8 kinds of window curve control

Near-field Gain control

4 levels of Background color control

Far-field Gain control

Sample with double frequency

Repetition Function

Measurement and Calculation


Normal Measurement and Calculation

Distance measurement, scale and angle measurement

Calculating area and circumstance with special ellipse

Heart rate calculation

Left-ventricle measurement

Measuring volume and weight with 3-axis method

Obstetric Calculation

Calculating pregnant time

Calculating the fetus¡¯s volume and the fetus¡¯s weight with two prameters

Display standard pregnant time table and estimate delivering date



Display Information

Display Format

10 inches 800 X 600 high-resolution monitor

Standard PAL-D, it can be connected to ultrasound workstation directly

Have the function to connect to the computer with the video adaptor

Display Language

Working surface language (English)

Menu language (Chinese or English)

Information Display

Probe type and frequency

Magnify scale

Focus number and position

Date and time: H/M/S  Y/M/D

Body symbol£º27 or above

Probe position sign

Patient number and name

Name of hospital or clinic

Electronic scale

Measurement result

Scan direction

Scan velocity of M or B/M mode

Grey scale

Frame frequency

Image process menu and current setting

Menu

Body Symbol

27 symbols in total

Body symbol for medicine: 4
Body symbol for maternity: 9
Body symbol for special part: 14

Image storage and display

Storage one image or display one storaged image

Cine loop

Standard 64 cine loop cards, 64 frames of cine loop


3000G1 B Ultrasonic Instrument
Features
1. Display Mode: B£¬2B£¬BM£¬Speed under BM or M mode: 2s, 4s, 6s, 8s/frame
2. Varied magnifications and the image is scrolled
3. Single point focus, multi-point focus, and dynamic focusing, low noise, wide frequency band receiving amplification circuit, 8 levels of TGC control, Changeable angle, Frame correlation, Grey alternative, Edge enhancement, Transverse filter, Dynamic filter, which make the image gradation is outstanding, lots of image disposing function make the image is clear and exquisite.

4. Measuring distance, perimeter, area (contrail or ellipse), volume, hart rate, velocity , fetus and etc.
5. Store 8 images, 192 frames of cine loop
6. Image up/down, left/right, black/white reverse
7. Gain control, brightness and contrast adjustment
8. Changeable probe, 4 kinds of scanning frequency changeable
9. Needle-guided brackets
10. Color display can be achieved
11. Body mark
12. Auto-input/display of the date, hospital, calculation formula, and so on

Specification
Probe: Basic probe: 3.5MHz R60 Convex probe
Optional Probes: 6.0MHz R13 Mini-Convex Probe
7.5MHz L40 Linear Probe
5.0MHz R20 Convex Probe
Double connectors
Scannig Mode: Electronic Linear, Electronic Convex
Shape: Trolley type
Monitor: 14¡± VGA high resolution black-white monitor
Power: AC 220V¡À22V, Frequency 50Hz¡À1Hz
Power consumption: ¡Ü250VA
Detectable Depth: ¡Ý170mm(3.5MHz R60 Convex probe)
Grey: 256
Accuracy error of geometric position: ¡Ü5£¥
Average no-problem working time: ¡Ý3000 hours


3000G2 B Ultrasonic Instrument

      This Ultrasonic diagnostic system is a kind of mobile system with advanced technology and mature functions; It combines varied innovating technologies of 256 gray scales and high density, broad band, big angle multi-frequency probe, is suitable for work in low, middle, high frequency. It is mainly used in the examination and diagnosis of abdomen, gynecology, OB/GYN, heart and small parts.

Features:
1. Can be equipped with six probes, broad frequency 2.5MHz-8.5MHz can meet kinds of clinic diagnostic requirements sufficiently.
2. The type of probes can be identified automatically.

3. Excellent sound absorption linear material, multi-layer acoustic permeated matching, high performance piezoelectricity material, which make probes have the advantage of broad band and higher sensitivity to improve the detection deep, distinguish and shorten scotoma.
4. Eliminating ultrasound spot, advancing the available signal is from the double return processing technology adopted.
5. Bog dynamic brand and band low noise pre-amplifier, dynamic multi-focus, dynamic variable aperture, dynamic filter, TGC, frame correlation, DSC change and repeat processing.

Main Function
Scaning Mode:B, B/B, B/M, M,varied magnifications and the image is scrolled.
Applications: Abdomen, gynecology, OB/GYN, heart and small parts.
Gray Scales: 256 levels
Cine-memory: 256 frames
Focus: Electronic focus, Acoustic lens focus, single focus and multiple focus
Image processing: Part zoom in real time, STC curve, cine loop, frame correlation, gamma adjustment, window curve control, image storage, edge enhancement, , image reverse function, dynamic range
Image Reversing: Left/Right, Up/Down, Positive/Negative
Measurement & Calculation: Distance, perimeter, area, volume, heart rate, depth, time, speed, Left Ventricle, Aorta, Mitral Valve, RV/LV, GS, BPD, CRL, FL, GL, TAD, OFD, AC, HC, pregnant week and fetal weight. It has OB report and LMP functions, 60 kinds of Body marks.
Character Display: date, time, ID, hospital name, measuring value, focus, gray scale, guage, probe position, probe type and frequency, display mode, multiple-ratio, scan direction, puncture guide line, focus, image process information and notes.
Power Supply: AC100-240V, Frequency:50Hz-60Hz
Other functions: Screen protects and probe protects, light keyboard, permanent storage and software update function.
Standard configuration: Main unit with SVGA, 3.5MHz convex probe, Deluxe trolley, 256 frames cine loop card

Options:
3.5MHz convex heart probe
6.0MHz convex vaginal probe
3.5MHz linear abdominal probe
3.5-6.5MHz linear rectal probe
7.5MHz linear facial probe
B/W video printer, 16 or 32 frames storage card