| RO-3000
series
Laptop(New)
3000D1
3000D2
3000G1
3000G2
|
|
|
Laptop(New)
This B ultrasound system is a portable
electronic convex scanning ultrasound
tomography inspection device with digital
scanning conversion. It has the features of
small bulk, light weight, large LCD screen
display and no eradiation.
|
|
Features£º
-
3.5MHZ
80 elements high-sensitive convex probe£¬
Optional: 5-7.5 MHz high-frequency probe.
-
15¡åTFT
LCD (abbr. Liquid Crystal Display)
-
Long
life, little noise.
-
image
processing, variable aperture, multi-stage
electronic focusing, logarithmic
compression, continuous STC control, dynamic
echo filtering, image enhancement, line
correlation, frame correlation, linear
interpolation, etc.
-
LCD,
high-sensitive imaging, various gray scales,
definite imaging, high-resolution ratio.
-
Display
mode: B, B/B, 4B, 8B,B+M and M imaging mode
-
Detectable
Depth:3.5MHz¡Ý160 mm
-
Magnification:
¡Á1.0, ¡Á1.2, ¡Á1.5, 2.0. ¡Á1.5, ¡Á2.0, with
depth-downward function
-
Gray
Scale:256
-
L
ine Number for Each Frame:160
-
Resolving
Power:Vertical ¡Ü1.0mm (depth¡Ü80mm);
¡Ü2.0mm (80mm<depth¡Ü130mm)£»
Horizontal ¡Ü2.0mm
(depth¡Ü80mm)£»
¡Ü3.0mm (80mm<depth¡Ü130mm)
-
Geometrical
Precision: Vertical ¡Ü5%
Horizontal ¡Ü8%
-
Blind
Zone:¡Ü5mm
-
Character
Display: Multi-remarks of name, gender, age,
number, various marks of body location
-
Focusing:
Variable aperture, 1-, 2-, 3-, and 4-stage
dynamic focusing for arbitrary option.
-
Measurements: Distance,
area/perimeter, cubage, HR and gestational
week£¨AC,HC,FL,BPD, GS ,CRL£©, etc
-
Note
Function: Name, Age, Sex£¬number of patient
recorder, diagnostic date, 24 markers of
body location, remarks in full screen, etc.
-
Gain
Control: 6-segment STC segmentation control,
full gain control
-
Image
Polarity: left/right turn, positive
/negative turn and up / down turn
-
Image
Memory: 128 frames
-
Cine
Loop and Frame: successive 128 frames
-
Pseudo
Color Function: 8 colors
-
¦Ã
rectification and pseudo color display,
character remarks in screen, Chinese or
English conversion of name, gender, age,
number at fixed remarks, FPGA designation.
-
Video
out: VGA
-
Output
Interface: two output interfaces, VGA and
PAL video signal outputs, can choose to
connect video printer
-
Standard
configuration: VGA video output external
interface to connect with the monitor, video
tape recorder, video image recorder.
-
Power
Supply Range: AC 220V¡À22V 50Hz¡À1Hz
-
Input
Power: ¡Ü260VA
-
Work
time: ¡Ý8h
-
Weight
¡Ö6.8kg
-
Shell
Size:384mm¡Á300mm¡Á125mm
|
|
|
|
3000D1 B Ultrasonic Instrument
Features
-
With
the advance of DSC and SMT, the apparatus
is more reliable compared with other
products.
-
By
adopting multistage dynamic focalizing,
variable aperture, digital scanning,
related digital graphic processing, etc,.
the apparatus can provide sensitive,
steady, clear, high-resolution pictures.
|
-
Equipped
with B, B+B, B+M,M display modes and the
256 gray scales screen.
-
Display
frozen pictures, two pictures in the same
frame, and freeze one of the two pictures
or both the two pictures. Moreover, the
displayed picture has the feature of
polarity reversal and bilateral reversal.
-
Magnifications
of picture are adjustable in the process
of operation.
-
Upgrade
of the depth of the picture.
-
Full
screen editable characters, real-time
clock, body-position indication, operation
indicator of Route Ball Mouse.
-
Multi-measurement
of length, perimeter, area, M-type
conventional examination and gestational
measurement.
-
Terminal
output of standard PAL system, which will
meet the requirement of different users.
-
Soft-touch
keyboard, plastic exterior case, which are
good-looking, portable, and convenient to
operate.
Applicable
fields
-
Suitable
of diagnosis of heart, liver, gallbladder,
kidney, spleen, pancreas, thyroid gland,
uterus, bladder and etc.
-
Widely
used for clinical examination and
diagnosis of abdomen and department of
obstetrics and gynecology in the hospitals
of county, rural-town and town.
-
Used
in the examinations of early pregnancy,
contraceptive ring, perinatal period of
pregnant woman, etc.
|
Configuration
Probe
|
3£®5MHz
Convex Probe£¨R=60£©
|
|
Optional
Probe
|
6£®5MHz
Convex Probe£¨Transvaginal R=13£©
7.5MHz High Frequency Linear Probe
|
|
Depth
Scope£¨mm£©
|
0-200mm
|
|
Maximal
Scanning Depth£¨mm£©
|
¡Ý170
|
|
Resolution
£¨mm£©
|
Horizontal
|
¡Ü3£¨Depth¡Ü80mm£©
¡Ü4£¨80mm<Depth¡Ü130mm£©
|
|
Vertical
|
¡Ü1£¨Depth¡Ü80mm£©
¡Ü2£¨80mm<Depth¡Ü130mm£©
|
|
Blind
Area£¨mm£©
|
¡Ü4
|
|
Accurancy£¨%£©
|
Horizontal
|
¡Ü10
|
|
Vertical
|
¡Ü5
|
|
Monitor
|
10
inches
|
|
Display
Mode
|
B¡¢B+B¡¢B+M¡¢M
|
|
Gray
Scale
|
256
|
|
Magnification
|
¡Á1.0£¬¡Á1.2£¬¡Á1.5£¬¡Á2
|
|
Cineloop
|
256
frames
|
|
Clock
|
Time
Display
|
|
Electronic
Focus
|
4
focus at radom
|
|
Frame
correlation
|
B¡¢B+B
|
|
Image
Reversal
|
Up/Down¡¢Left/Right¡¢Black/White
|
|
Measurement
|
Distance¡¢Perimeter¡¢area¡¢heart
rate¡¢pregnant weeks
|
|
Character
Mark
|
Date,
ID, Age, Sex, Focus, Frame
Correlation, Full Screen Character
|
|
Body
Mark
|
18
kinds
|
|
Power
Consumption£¨MAX£©
|
110VA
|
¡¡
|
|
|
|
3000D2 B Ultrasonic Instrument
3000D2 adopts lots of advanced
electrical and faced technique. Digital
transmitting focus control improve the
precision of the transmitting point
which improve the image distinguish; low
noise, wide frequency band receiving
amplification circuit enriches the
message which make the image gradation
is outstanding; lots of image disposing
function make the image is clear and
exquiste.
|
|
Main
features of Convex Probe:
|
Serial No.
|
Features
|
Specifications
|
|
1
|
Probe
Frequency Rating MHz
|
3.5
|
2.5
(frequency conversion)
|
5.0
(frequency conversion
|
|
2
|
Horizontal
Resolution,mm
|
¡Ü3(Depth¡Ü80)
¡Ü4(80<Depth¡Ü130)
|
¡Ü3(Depth¡Ü80)
¡Ü5(80< Depth¡Ü160)
|
¡Ü2(Depth¡Ü40)
¡Ü3(40< Depth¡Ü80)
|
|
3
|
Vertical
Resolution, mm
|
¡Ü2(Depth¡Ü80)
¡Ü3(80<Depth¡Ü130)
|
¡Ü2(Depth¡Ü130)
¡Ü3(130<Depth¡Ü170)
|
¡Ü1(Depth¡Ü40)
¡Ü2(40<Depth¡Ü80)
|
|
4
|
Blind
Area, mm
|
¡Ü5
|
¡Ü6
|
¡Ü3
|
|
5
|
Maximum
depth of detection, mm
|
¡Ý160
|
¡Ý180
|
¡Ý100
|
|
6
|
Accuracy
error of geometric position %
|
Horizontal¡Ü15
Vertical¡Ü10
|
Horizontal¡Ü15
Vertical¡Ü10
|
Horizontal¡Ü10
Vertical¡Ü10
|
Main
features of Transvaginal Probe:
|
Serial No.
|
Features
|
Specifications
|
|
1
|
Probe
Frequency Rating MHz
|
6.5
|
5.5
(frequency conversion)
|
8.0(frequency
conversion
|
|
2
|
Horizontal
Resolution,mm
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
|
3
|
Vertical
Resolution, mm
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
|
4
|
Blind
Area, mm
|
¡Ü7
|
¡Ü7
|
¡Ü7
|
|
5
|
Maximum
depth of detection, mm
|
¡Ý60
|
¡Ý70
|
¡Ý60
|
|
6
|
Accuracy
error of geometric position %
|
Horizontal¡Ü10
Vertical¡Ü5
|
Horizontal¡Ü10
Vertical¡Ü5
|
Horizontal¡Ü10
Vertical¡Ü5
|
Main
features of High Frequency Linear Probe:
|
Serial No.
|
Features
|
Specifications
|
|
1
|
Probe
Frequency Rating MHz
|
7.5
|
6.0(frequency
conversion)
|
9.0(frequency
conversion
|
|
2
|
Horizontal
Resolution,mm
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
|
3
|
Vertical
Resolution, mm
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
¡Ü1(Depth¡Ü40)
|
|
4
|
Blind
Area, mm
|
¡Ü4
|
¡Ü4
|
¡Ü4
|
|
5
|
Maximum
depth of detection, mm
|
¡Ý60
|
¡Ý60
|
¡Ý60
|
|
6
|
Accuracy
error of geometric position %
|
Horizontal¡Ü5
Vertical¡Ü5
|
Horizontal¡Ü5
Vertical¡Ü5
|
Horizontal¡Ü5
Vertical¡Ü5
|
Working
Mode
|
Scanning Mode
|
Linear,
Convex, Double connectors
|
|
Scanning
Line
|
512
|
|
Display
Mode
|
B¡¢B/B¡¢B/M¡¢M
|
|
Focus
|
Electronic
Focusing, Acoustic lens focusing
|
|
In
B¡¢B/B Mode
|
Single
Focus¡¢Double Focus¡¢Three Focus¡¢Four
Focus
|
|
In
B/M¡¢M Mode
|
Single
Focus for four areas
|
Features
|
Gray
|
256
|
|
Display
depth
|
Convex
Probe Maximum 220mm£¬scroll
Transvaginal Probe Maximum
120mm,scroll
High frequency Maximum 120mm£¬scroll
|
|
Picture
analyse
|
|
3
levels of working frequency
|
Left/Right
Reverse
|
|
8
levels of edge enhancement
|
Up/Down
Reverse
|
|
8
levels of dynamic range
|
Positive/Negative
Reverse
|
|
4
levels of frame average processing
|
4
Magnification rates
|
|
4
kinds of gamma correction
|
Gain
control
|
|
8
kinds of window curve control
|
Near-field
Gain control
|
|
4
levels of Background color control
|
Far-field
Gain control
|
|
Sample
with double frequency
|
Repetition
Function
|
Measurement
and Calculation
|
Normal Measurement and Calculation
|
|
Distance
measurement, scale and angle
measurement
|
|
Calculating
area and circumstance with special
ellipse
|
|
Heart
rate calculation
|
|
Left-ventricle
measurement
|
|
Measuring
volume and weight with 3-axis method
|
|
Obstetric
Calculation
|
|
Calculating
pregnant time
|
|
Calculating
the fetus¡¯s volume and the
fetus¡¯s weight with two prameters
|
|
Display
standard pregnant time table and
estimate delivering date
|
Display Information
Display
Format
|
|
10
inches 800 X 600 high-resolution
monitor
|
|
Standard
PAL-D, it can be connected to
ultrasound workstation directly
|
|
Have
the function to connect to the
computer with the video adaptor
|
Display
Language
|
|
Working
surface language (English)
|
|
Menu
language (Chinese or English)
|
|
Information
Display
|
|
Probe
type and frequency
|
Magnify
scale
|
|
Focus
number and position
|
Date
and time: H/M/S Y/M/D
|
|
Body
symbol£º27 or above
|
Probe
position sign
|
|
Patient
number and name
|
Name
of hospital or clinic
|
|
Electronic
scale
|
Measurement
result
|
|
Scan
direction
|
Scan
velocity of M or B/M mode
|
|
Grey
scale
|
Frame
frequency
|
|
Image
process menu and current setting
|
Menu
|
Body
Symbol
|
|
27
symbols in total
|
|
Body
symbol for medicine: 4
Body symbol for maternity: 9
Body symbol for special part: 14
|
|
Image
storage and display
|
|
Storage
one image or display one storaged
image
|
|
Cine
loop
|
|
Standard
64 cine loop cards, 64 frames of
cine loop
|
|
|
|

|
3000G1 B Ultrasonic Instrument
Features
1. Display Mode: B£¬2B£¬BM£¬Speed under BM
or M mode: 2s, 4s, 6s, 8s/frame
2. Varied magnifications and the image is
scrolled
3. Single point focus, multi-point focus, and
dynamic focusing, low noise, wide frequency
band receiving amplification circuit, 8 levels
of TGC control, Changeable angle, Frame
correlation, Grey alternative, Edge
enhancement, Transverse filter, Dynamic
filter, which make the image gradation is
outstanding, lots of image disposing function
make the image is clear and exquisite.
|
|
4.
Measuring distance, perimeter, area (contrail
or ellipse), volume, hart rate, velocity ,
fetus and etc.
5. Store 8 images, 192 frames of cine loop
6. Image up/down, left/right, black/white
reverse
7. Gain control, brightness and contrast
adjustment
8. Changeable probe, 4 kinds of scanning
frequency changeable
9. Needle-guided brackets
10. Color display can be achieved
11. Body mark
12. Auto-input/display of the date, hospital,
calculation formula, and so on
Specification
Probe: Basic probe: 3.5MHz R60 Convex probe
Optional Probes: 6.0MHz R13 Mini-Convex Probe
7.5MHz L40 Linear Probe
5.0MHz R20 Convex Probe
Double connectors
Scannig Mode: Electronic Linear, Electronic
Convex
Shape: Trolley type
Monitor: 14¡± VGA high resolution black-white
monitor
Power: AC 220V¡À22V, Frequency 50Hz¡À1Hz
Power consumption: ¡Ü250VA
Detectable Depth: ¡Ý170mm(3.5MHz R60 Convex
probe)
Grey: 256
Accuracy error of geometric position: ¡Ü5£¥
Average no-problem working time: ¡Ý3000 hours
|
|
|

|
3000G2 B Ultrasonic Instrument
This Ultrasonic diagnostic system is a kind of
mobile system with advanced technology and
mature functions; It combines varied
innovating technologies of 256 gray scales and
high density, broad band, big angle
multi-frequency probe, is suitable for work in
low, middle, high frequency. It is mainly used
in the examination and diagnosis of abdomen,
gynecology, OB/GYN, heart and small parts.
Features:
1. Can be equipped with six probes, broad
frequency 2.5MHz-8.5MHz can meet kinds of
clinic diagnostic requirements sufficiently.
2. The type of probes can be identified
automatically.
|
|
3.
Excellent sound absorption linear material,
multi-layer acoustic permeated matching, high
performance piezoelectricity material, which
make probes have the advantage of broad band
and higher sensitivity to improve the
detection deep, distinguish and shorten
scotoma.
4. Eliminating ultrasound spot, advancing the
available signal is from the double return
processing technology adopted.
5. Bog dynamic brand and band low noise
pre-amplifier, dynamic multi-focus, dynamic
variable aperture, dynamic filter, TGC, frame
correlation, DSC change and repeat processing.
Main Function
Scaning Mode:B, B/B, B/M, M,varied
magnifications and the image is scrolled.
Applications: Abdomen,
gynecology, OB/GYN, heart and small parts.
Gray Scales: 256 levels
Cine-memory: 256 frames
Focus: Electronic focus,
Acoustic lens focus, single focus and multiple
focus
Image processing: Part zoom in real time, STC
curve, cine loop, frame correlation, gamma
adjustment, window curve control, image
storage, edge enhancement, , image reverse
function, dynamic range
Image Reversing: Left/Right,
Up/Down, Positive/Negative
Measurement & Calculation: Distance,
perimeter, area, volume, heart rate, depth,
time, speed, Left Ventricle, Aorta, Mitral
Valve, RV/LV, GS, BPD, CRL, FL, GL, TAD, OFD,
AC, HC, pregnant week and fetal weight. It has
OB report and LMP functions, 60 kinds of Body
marks.
Character Display: date,
time, ID, hospital name, measuring value,
focus, gray scale, guage, probe position,
probe type and frequency, display mode,
multiple-ratio, scan direction, puncture guide
line, focus, image process information and
notes.
Power Supply: AC100-240V, Frequency:50Hz-60Hz
Other functions: Screen
protects and probe protects, light keyboard,
permanent storage and software update
function.
Standard configuration: Main unit with SVGA,
3.5MHz convex probe, Deluxe trolley, 256
frames cine loop card
Options:
3.5MHz convex heart probe
6.0MHz convex vaginal probe
3.5MHz linear abdominal probe
3.5-6.5MHz linear rectal probe
7.5MHz linear facial probe
B/W video printer, 16 or 32 frames storage
card
|
|
|
|
|
|